Ignition Systems GFI.
Resume: |
|
Supply voltage: |
220 – 230 VAC (-15/+10 %). 50/60 Hz |
Ignition voltage: |
5 kV/10 kV |
Power consumption: |
100 VA ignition transformer |
Electrical connection: |
Cable, prewired (standard), plug and socket connector with pre-assembled cabl |
Cable length: |
2 m – 100 m, Standard = 5 m |
IP protection: |
IP 65/IP 67 |
Housing: |
Sea water resistant aluminium (standard) stainless steel (1.4301/1.4404) |
Coating: |
non (standard) |
Tube length: |
240 – 15.000 mm |
Tube: |
Stainless steel 1.4301, heat resistant end tube14.841 (standard) Stainless steel 1.4571 heat resistant end tube 14.841 (option) |
Fuel gas: |
Natural gas, propane/butane (standard) coke oven gas, refinery gas (option) |
Fuel gas supply pressure: |
50 – 200 mbar above combustion pressure (standard) Orifice for higher pressure (option) |
Air suppl pressurer: |
Depending on the size |
Cooling air flow: |
Depending on the size, at least 50 % of combustion air flow |
Approvals: |
For SIL 2 ionisation flame monitoring device: kiwa 2009/142/EG UL |
|
For SIL 3 flame monitoring device F130I: 2009/142/EC |